10-4Adaptec Ultra320 SCSI Cards User’s GuideLoading the Driver at Server BootupTo automatically load the adpu320.ham at server bootup, thestartup.ncf file (usually located in your server’s startup directory)must contain a load command line that specifies the location of thedriver and any appropriate command line options (see Using theLoad Command Line Options on page 10-5). For additionalinformation on the startup.ncf file, refer to your NetWaredocumentation.The correct syntax to load the driver is:load [pathname]adpu320.ham [options]For example, the command line to load the driver from thec:\nwserver directory, with the verbose= option on is:load c:\nwserver\adpu320 verbose=yCommand line options are not case sensitive. Placing commasbetween command line options is optional. See Using the LoadCommand Line Options on page 10-5 for possible values.To modify the startup.ncf file, type load nwconfig and pressEnter.Note: You can also use your DOS text editor to modify thestartup.ncf file.