4-12Adaptec Ultra320 SCSI Cards User’s Guide2Select a drive and pressEnter. SelectYeswhen the followingmessage appears:Are you Sure?Yes/NoAfter you select your spare drive, it will appear as a spare in theMain menu.Rebuilding ArraysNote:Rebuilding applies to Fault Tolerant arrays (RAID 1 andRAID 10) only.If an array Build process (or initialization) is interrupted or criticalwith one member missing, you must perform a Rebuild to get thearray to Optimal status. For a critical array Rebuild operation, theoptimal drive is the source drive.Note:If no spare exists and a hard disk drive fails, you need tocreate a spare before you can rebuild an array. SeeAdding aSpare Driveon page 4-11 before continuing your Rebuild.To rebuild an array for RAID 1 or RAID 10:1From the Main menu, select array for Rebuild and pressEnter.2PressRfor Rebuild.AdaptecSCSISelect(TM)Utility vX.XXTypeMirrored (R1)Hard DriveSpareIDVendorProductSize00030303Hard DriveQuantumAdaptecQuantumQuantumHostRAID-AXP3227WXP3227WXP3227W2GB2GB2GB2GBOptimalFreeOptimalFreeCreate, Spare, Delete, Rebuild, Verify, Bootable39320A at slot 03, 00:0F:00V move cursor, accept option, exitStatus