Central Site Remote Access Switch 519SYSTEM M ESSAGESSystem Message SummaryMissing BEARER_CAPABILITY in HOST_CALL_REQUESTMissing CALLED_NUMBER_IE in HOST_CALL_REQUESTMissing CHANNEL in HOST_CALL_REQUESTMissing CHANNEL_ID_IE in HOST_CALL_REQUESTMissing TN in HOST_CALL_REQUESTAn error has been detected in the R2 or RBS signaling procedure, and will typically result in a failedcall. The error was due to unrecognizable or incorrect information. Check configuration; ifproblem persists, contact your Distributor or Customer Support.MODEM of DM card in slot is unusableAn attempt was made to perform an operation on a specific modem that had been deleted from theusable list via the modem delete command. Use themodem add command to make the modemusable again, or use a different modem to perform the desired operation.MODEM CONNECT failed - connect , board , modem An attempted modem call has failed to connect. Try reconnecting the call again. If this messageconsistently appears for the same modem number, contact your distributor or Customer Support.Modem revision on modem of slot failedIndividual modems on a Digital Modem card are failing. Check the hardware and softwareconfigurations, as well as the seating of the card and the MVIP cabling. If all seems in order, contactyour Distributor or Customer Support.Modem version comparison failed in slot due to inconsistent formatThis message displays if any of the following files are corrupted: DM56MDM.MOT,DM56PPCU.MOT, DM24MDMU.MOT, DM24PPCU.MOT. Contact your Distributor or CustomerSupport.Negotiation Failure with Semipermanent device “x”There was some problem negotiating a connection with device "x." There was no way to send data.This could be an authentication failure or a PPP failure.Network loop between site1 and site 2The system detected a WAN loop between the specified sites, so the System will not forward theduplicate frame. Check the System and network configuration for this loop and adjust.Network requested init but no SPID configured- Slot= Port= Ces=endpoint suffix>A SPID is required but is not configured on the indicated line. The configuration of theCyberSWITCH or of the switch should be corrected.Network sent bad Endpoint identifier - Slot= Port= Ces=suffix>During terminal initialization, a bad endpoint identifier was received on the indicated line. Thismessage is informational only; your line should continue to operate normally.Network sent CAUSE - invalid SPID - Slot= Port= Ces=suffix>An invalid SPID is configured on the indicated line. The configuration of the CyberSWITCH or ofthe switch should be corrected. PreviousNext |