Central Site Remote Access Switch 527SYSTEM M ESSAGESSystem Message SummarySecurity Rejection - Bridge Address Security cannot use Authentication ServerBoth options (Bridge Address Security and off-node User Authentication) are not supportedsimultaneously.Security Rejection - Caller did not negotiate securityBridge Security is configured. A caller attempted to send device data before (or without)negotiating the Bridge Address security.Security Rejection - HDLC not supported by the callerA properly formed Bridge Security negotiation packet was received but the remote bridgeindicated that it did not support the HDLC protocol.Security Rejection - Invalid Calling Line Id - The calling line identifier has not been configured for any valid device in the system Device list. Thenumber indicates the actual number presented by the network.Security Rejection - Invalid Password () givenA properly formed Bridge Security negotiation packet was received. The bridge is registered in theSystem Device table and a password was provided, but the password provided did not match thepassword in the System Device table.Security Rejection - No Bridge Address given by callerA normal Bridge Security negotiation packet was received, but did not contain a bridge address.Check configuration. If problem persists, contact your Distributor or Customer Support.Security Rejection - No Password given by callerA properly formed Bridge Security negotiation packet was received, and the bridge is registered inthe system Device Table, but a password is required and none was provided by the calling bridge.Check configuration. If problem persists, contact your Distributor or Customer Support.Security Rejection - No Protocol List suppliedA Combinet has attempted to connect to the system without the required Protocol List information.Check configuration, and then reboot the Combinet. If problem persists, contact your Distributoror Customer Support.Security Rejection - Timeout on Startup CompleteAfter a normal Bridge Security negotiation packet is received, and the System sends a responsemessage, there is a five second time limit in which a “Startup Complete” message must be received.The above security rejection message is seen if the Startup Complete message is not received beforethe timer expires. Check to see if the response message was received by the calling bridge.Security Rejection - Unknown Calling Bridge - A properly formed Bridge Security negotiation packet was received but the bridge address is notregistered in the system Device Table.SemiPermanent. Local authentication failure of Semipermanent device "x"The system failed to authenticate the indicated device. The semipermanent connection will bedisabled. Compare the authentication device information configured on the system with the actualconfiguration of the remote device. Make corrections as needed. Then, issue thecall device name> command to reinstate the semipermanent connection. PreviousNext |