USER’S GUIDE542 CyberSWITCHX25 facilities error, facility not availableA facility was requested which is not enabled. Verify that the specific facility is enabled by bothDTE’s and the service provider.X25 facilities error, packet length negotiation not allowedThe DTE packet length does not match the packet length available at either the DCE or the remoteDTE, and packet length negotiation is not enabled. You should enable packet length negotiation atboth DTE’s. If this is not possible, or does not work, select the same packet length at both DTE’s.X25 facilities error, window size negotiation not availableThe DTE window size does not match the window size available at either the DCE or the remoteDTE, and window size negotiation is not enabled. You should enable window size negotiation atboth DTE’s. If this is not possible, or does not work, select the same window size at both DTE’s.X25 facilities error, RPOA not availableRecognized Private Operating Agency selection is not available. The System does not support thisfeature.X25 facilities warning, transit delay not availableThe service provider does provide transit delay information. No action required.X25 facilities warning, charge inform not availableThe service provider does provide charging information. No action required.X25 facilities warning, call redirect notification not availableThe service provider does provide call redirect information. No action required.X25 facilities warning, NUI not availableNetwork device identification not available. No action required.X25 permanent virtual circuit down: Access=, PVC=, LCN=The indicated X.25 virtual circuit is down. Switched backup connections will be used, if available.This message will occur if the other system is down, or if the network interface line is not connected,or if the authentication of the remote device failed.X25 permanent virtual circuit to device up: Access=, PVC=,LCN=The indicated X.25 virtual circuit is operational.XMODEM DATA FAILED CRC CHECKSA file contained in the X-Modem file set has failed the CRC check. The system will automaticallyreset and attempt a reboot in an effort to correct the problem. If the system continues to fail, makenote of the displayed messages, and call your distributor. A software update is likely needed.Zone allocation failed, increase zone table capacity.The number of AppleTalk zones has surpassed the configured zone table capacity. TheCyberSWITCH configuration utility allows you to set the maximum number of defined andlearned zone table entries. The default value is 512. The maximum is 2,000. You may need to resetthe zone table capacity to a higher number. PreviousNext |