Central Site Remote Access Switch 641SYSTEM S TATISTICSFrame Relay Statistics# Lost Rx FrameRelated to the “# Lost Rx Seq” counter in that it represents the number of actual lost frames, not justthe number of times a frame (or frames) was lost.# Invalid Frame SizeThe number of times a frame is discarded because it exceeded the maximum frame size supportedby the frame relay network.# Timed Lost Rx FrameNot currently supported.# No Control BlockNot currently supported.# NEW & Existing PVCThe number of times a NEW PVC was indicated by a LMI STATUS message—but the frame relaysoftware believed the PVC already existed.# PVC Not ConfiguredThe number of times a frame was received containing an unknown DLCI value, and hence, anunconfigured PVC.# No NEW BitNot currently supported.# Not Full ENQUIRYThe number of times a STATUS message was received containing a LINK INTEGRITYVERIFICATION ONLY report type, when in fact a FULL REPORT was expected.# Errored Full ENQUIRYThe number of times an errored STATUS message was received of type FULL REPORT.# Delete Absent PVCNot currently supported.# Errored LMI HeaderThe number of LMI frames received in which the LMI encapsulation header was errored.PVC R ELATED STATISTICSPVC StateThe condition of the Frame Relay Permanent Virtual Circuit. Possible values are: TERMINATED,INIT, NOT READY, and NETWORK OUTAGE. The definitions for the possible values are as follows:TERMINATEDThe PVC state entered when the PVC has been dynamically removed.INITThe PVC state entered when the PVC is ready for use.