User Constant Tables5- 49Analog Inputs: H3User constants for analog inputs are shown in the following table.32Speed control circuit operating for torque control (except when stopped).The external torque reference will be limited if torque control is selected(internal torque reference < external torque reference).Output when the motor is rotating at the speed limit.No No No Yes 6-13033 Zero-servo end (ON: Zero-servo function completed) No No No Yes 6-896-14537 During run 2 (ON: Frequency output, OFF: Base block, DC injection brak-ing, initial excitation, operation stop) Yes Yes Yes Yes 6-89Con-stantNumberName Description SettingRangeFactorySettingChangeduringOpera-tionControl Methods MEMOBUSRegis-terPageV/fV/fwithPGOpenLoopVec-torFluxVec-torH3-01Signal levelselection(terminalA1)0: 0 to ±10V1: 0 to ±10V 0 or 1 0 No A A A A 410H 6-35H3-02 Gain (termi-nal A1)Sets the frequency when 10V is input, as a percentage ofthe maximum output fre-quency.0.0 to1000.0 100.0% Yes A A A A 411H 6-35H3-03 Bias (termi-nal A1)Sets the frequency when 0 Vis input, as a percentage ofthe maximum frequency.-100.0to+100.00.0% Yes A A A A 412H 6-35H3-04Signal levelselection(terminalA3)0: 0 to ±10V1: 0 to ±10V 0 or 1 0 No A A A A 413H 6-356-129H3-05Multi-func-tion analoginput (ter-minal A3)functionselectionSelect from the functionslisted in the following table.Refer to the next page.0 to 1F 1F No A A A A 414H 6-356-129H3-06 Gain (termi-nal A3)Sets the input gain (level)when 10V is input.Set according to the 100%value selected from H3-05.0.0 to1000.0 100.0% Yes A A A A 415H 6-356-129H3-07 Bias (termi-nal A3)Sets the input gain (level)when 0V is input.Set according to the 100%value selected from H3-05.-100.0to+100.00.0% Yes A A A A 416H 6-356-129Set-tingValueFunctionControl MethodsPageV/fV/fwithPGOpenLoopVec-torFluxVec-tor