6 -156OptionsThis section explains the Inverter option functions. Performing Speed Control with PGThis section explains functions with V/f control with PG .Related ConstantsCon-stantNumberName Description SettingRangeFactorySettingChangeduringOpera-tionControl Methods MEMOBUSRegis-terV/fV/fwithPGOpenLoopVec-torFluxVec-torF1-01 PG constantSets the number of PG (pulsegenerator or encoder) pulses.Sets the number of pulses permotor revolution.0 to60000 600 No No Q No Q 380HF1-02Operationselection atPG open cir-cuit (PGO)Sets the PG disconnection stop-ping method.0: Ramp to stop (Decelerationstop using DecelerationTime 1, C1-02.)1: Coast to stop2: Fast stop (Emergency stopusing the deceleration timein C1-09.)3: Continue operation (Toprotect the motor ormachinery, do not normallymake this setting.)0 to 3 1 No No A No A 381HF1-03Operationselection atoverspeed(OS)Sets the stopping method whenan overspeed (OS) fault occurs.0: Ramp to stop (Decelerationstop using DecelerationTime 1, C1-02.)1: Coast to stop2: Fast stop (Emergency stopusing the deceleration timein C1-09.)3: Continue operation (Toprotect the motor ormachinery, do not normallymake this setting.)0 to 3 1 No No A No A 382HF1-04Operationselection atdeviationSets the stopping method when aspeed deviation (DEV) faultoccurs.0: Ramp to stop (Decelerationstop using DecelerationTime 1, C1-02.)1: Coast to stop2: Fast stop (Emergency stopusing the deceleration timein C1-09.)3: Continue operation (DEV isdisplayed and operationcontinued.)0 to 3 3 No No A No A 383Hand flux vector control