Digital Operator Functions6-147Digital Operator FunctionsThis section explains the Digital Operator functions. Setting Digital Operator FunctionsYou can set Digital Operator-related constants such as selecting the Digital Operator display, multi-functionselections, and copy functions.Related ConstantsCon-stantNumberName Description SettingRangeFactorySettingChangeduringOpera-tionControl Methods MEMOBUSRegis-terV/fV/fwithPGOpenLoopVec-torFluxVec-toro1-02Monitorselection afterpower upSets the monitor item to be dis-played when the power is turnedon.1: Frequency reference2: Output frequency3: Output current4: The monitor item set for o1-011 to 4 1 Yes A A A A 501Ho1-03Frequencyunits of refer-ence settingand monitorSets the units that will be set anddisplayed for the frequency ref-erence and frequency monitor.0: 0.01 Hz units1: 0.01% units (Maximumoutput frequency is 100%)2 to 39:min -1 units (Sets the motorpoles.)40 to 39999:User desired displaySet the desired values forsetting and display for the max.output frequency.Example: When the max. out-put frequency value is 200.0, set120000 to39999 0 No A A A A 502Ho1-04Setting unitfor frequencyconstantsrelated to V/fcharacteris-ticsSet the setting unit for frequencyreference-related constants.0: Hz1: min−10 or 1 0 No No No No A 503Ho2-01LOCAL/REMOTEkey enable/disableSets the Digital Operator Local/Remote Key0: Disabled1: Enabled (Switches betweenthe Digital Operator and theconstant settings.)0 or 1 1 No A A A A 505HSet 4-digit numberexcluding the decimalpoint.Set the number of digitsbelow the decimal pointto display.