User Constant Tables5- 69 Digital Operator Constants: oThe following settings are made with the Digital Operator constants (o constants): Multi-function selectionsand the copy function.Monitor Select: o1User constants for Digital Operator Displays are shown in the following table.Con-stantNumberName Description SettingRangeFactorySettingChangeduringOpera-tionControl Methods MEMOBUSRegis-terPageV/fV/fwithPGOpenLoopVec-torFluxVec-toro1-01 MonitorselectionSet the number of the moni-tor item to be displayed inthe earliest 4 monitor items.(U1-)The output monitor voltage(factory setting) can bechanged.4 to 99 6 Yes A A A A 500H -o1-02Monitorselectionafter powerupSets the monitor item to bedisplayed when the power isturned on.1: Frequency reference2: Output frequency3: Output current4: The monitor item set foro1-011 to 4 1 Yes A A A A 501H 6-147o1-03Frequencyunits of ref-erence set-ting andmonitorSets the units that will be setand displayed for the fre-quency reference and fre-quency monitor.0: 0.01 Hz units1: 0.01% units(Maximum outputfrequency is 100%)2 to 39:min-1 units (Sets the motorpoles.)40 to 39999:User desired displaySet the desired values forsetting and display for themax. output frequency.Example: When the max.output frequency value is200.0, set 120000 to39999 0 No A A A A 502H 6-1476-164Set 4-digit numberexcluding the decimalpoint.Set the number of digitsbelow the decimal pointto display.