6 -90Monitor ConstantsThis section explains the analog monitor and pulse monitor constants. Using the Analog Monitor ConstantsThis section explains the analog monitor constants.Related ConstantsCon-stantNumberName Description SettingRangeFactorySettingChangeduringOpera-tionControl Methods MEMOBUSRegis-terV/fV/fwithPGOpenLoopVec-torFluxVec-torH4-01Monitorselection (ter-minal FM)Sets the number of the monitoritem to be output (U1-)from terminal FM. The monitoritems that can be set depends onthe control method.4, 10 to 14, 25, 28 to 31, 34, 35,39 to 43 cannot be set.1 to 99 2 No A A A A 41DHH4-02 Gain (termi-nal FM)Sets the multi-function analogoutput 1 voltage level gain.Sets whether the monitor itemoutput will be output in multi-ples of 10 V.The maximum output from theterminal is 10 V.A meter calibration function isavailable.0.00 to2.50 1.00 Yes Q Q Q Q 41EHH4-03 Bias (termi-nal FM)Sets the multi-function analogoutput 1 voltage level bias.Sets output characteristic up/down parallel movement as apercentage of 10 V.The maximum output from theterminal is 10 V.A meter calibration function isavailable.-10.0 to+10.0 0.0% Yes A A A A 41FHH4-04Monitorselection (ter-minal AM)Sets the number of the monitoritem to be output (U1-)from terminal AM.The monitor items that can beset depends on the controlmethod.4, 10 to 14, 25, 28 to 31, 34, 35,39 to 43 cannot be set.1 to 99 3 No A A A A 420HH4-05 Gain (termi-nal AM)Set the voltage level gain formulti-function analog output 2.Set the number of multiples of10 V to be output as the 100%output for the monitor items.The maximum output from theterminal is 10 V.A meter calibration function isavailable.0.00 to2.50 0.50 Yes Q Q Q Q 421H