Options6-163Related ConstantsSetting PrecautionsAlways set b1-01 (Reference selection) to 1 (control circuit terminal) when using the AI-14B for three chan-nels of independent inputs. When this is done, H1-01 to H1-06 (multi-function contact inputs) cannot be set to2 (Option/Inverter selection). Using a Digital Reference Board (SPEC: E or Later Only)When using a DI-08 or DI-16H2 Digital Reference Board, set b1-01 (Reference selection) to 3 (OptionBoard).The DI-16H2 can be used to set a frequency using a 16-bit digital reference. The DI-08 can be used to set afrequency using a 8-bit digital reference.Related ConstantsCon-stantNumberName Description SettingRangeFactorySettingChangeduringOpera-tionControl Methods MEMOBUSRegis-terV/fV/fwithPGOpenLoopVec-torFluxVec-torF2-01Bi-polar oruni-polarinput selec-tionSets the functions for channel 1to 3 which are effective whenthe AI-14B Analog ReferenceBoard is used.0: 3-channel individual (Chan-nel 1: terminal A1, Channel2: terminal A2, Channel 3:terminal A3)1: 3-channel addition (Additionvalues are the frequency ref-erence)When set to 0, select 1 for b1-01. In this case the multi-func-tion input “Option/Inverterselection” cannot be used.0 or 1 0 No A A A A 38FHCon-stantNumberName Description SettingRangeFactorySettingChangeduringOpera-tionControl Methods MEMOBUSRegis-terV/fV/fwithPGOpenLoopVec-torFluxVec-torF3-01 Digital inputoptionSets the Digital Reference Boardinput method.0: BCD 1% unit1: BCD 0.1% unit2: BCD 0.01% unit3: BCD 1 Hz unit4: BCD 0.1 Hz unit5: BCD 0.01 Hz unit6: BCD special setting (5-digitinput)7: Binary input6 is only effective when the DI-16H2 is used.When o1-03 is set to 2 or higher,the input will be BCD, and theunits will change to the o1-03setting.0 to 7 0 No A A A A 390H