Defaults 20 secondsCommand Modes CONFIGURATIONCommand History This guide is platform-specific. For command information about other platforms, see the relevant Dell NetworkingOS Command Line Reference Guide.Version Description9.10(0.0) Introduced on the S6100-ON.9.8(1.0) Introduced on the Z9100-ON.9.8(0.0P5) Introduced on the S4048-ON.9.8(0.0P2) Introduced on the S3048-ON.9.7(0.0) Introduced on the S6000-ON.9.2(1.0) Introduced on the Z9500.9.0.2.0 Introduced on the S6000.8.3.19.0 Introduced on the S4820T.8.3.11.1 Introduced on the Z9000.8.3.7.0 Introduced on the S4810.8.2.1.0 Introduced on S-Series Stacking.8.1.1.0 Introduced on the E-Series.7.7.1.0 Introduced on the S-Series.7.6.1.0 Introduced on the C-Series.7.4.1.0 Introduced on the E-Series.Usage Information The polling interval for an interface is the maximum number of seconds between successive samples of counterssent to the collector. This command changes the global default counter polling (20 seconds) interval. You canconfigure an interface to use a different polling interval.Related Commands • sflow polling-interval (Interface) — sets the polling interval for an interface.sflow polling-interval (Interface)Set the sFlow polling interval at an interface (overrides the global-level setting.)Syntax sflow polling-interval interval valueTo return to the default, use the no sflow polling-interval interval command.Parameters interval value Enter the interval value in seconds. The range is from 15 to 86400 seconds. The default isthe global counter polling interval.Defaults The same value as the current global default counter polling interval.Command Modes INTERFACE1488 sFlow