Oct 8 09:26:25: %RPM1:RP1 %BGP-5-ADJCHANGE: Connection with neighbor 1.1.14.2closed. Neighbor recycled--More--Example (History) Dell#show logging historySyslog History Table: 1 maximum table entries,saving level Warnings or higherSNMP notifications not Enabled%RPM:0:0 %CHMGR-2-LINECARDDOWN - Line card 3 down - IPC timeoutDell#show logging driverlog stack-unitDisplay the driver log for the specified hardware component.Syntax show logging driverlog stack-unit stack-unit-numberParameters stack-unit stack-unit-numberEnter the keywords stack-unit followed by the stack member ID of the switch forwhich you want to display the driver log.defaults noneCommand Modes • EXEC• EXEC PrivilegeCommand History This guide is platform-specific. For command information about other platforms, see the relevant Dell NetworkingOS Command Line Reference Guide.Version Description9.10(0.0) Introduced on the S6100–ON.9.8(1.0) Introduced on the Z9100–ON.9.8(0.0P5) Introduced on the S4048-ON.9.8(0.0P2) Introduced on the S3048-ON.9.7(0.0) Introduced on the S6000-ON.9.2(1.0) Introduced on the Z9500.9.2(0.0) Introduced on the M I/O Aggregator. This command is supported in Programmable-Mux(PMUX) mode only.9.0.2.0 Introduced on the S6000.8.3.19.0 Introduced on the S4820T.8.3.11.1 Introduced on the Z9000.8.3.7.0 Introduced on the S4810.7.6.1.0 Introduced on the S-Series.Example Dell#show logging driverlog stack-unit 10:Task(tUsrRoot): [ 491677]PSU FanCtrl Drv ERR:ssnDrvPoePsuEepromWriteEnable : 66 - Psu 1 is Not Present Cannot enable1:Task(tUsrRoot): [ 338]PSU FanCtrl Drv ERR: ssnDrvPsuFanCtrlInit : 118 -1538 Simple Network Management Protocol (SNMP) and Syslog