Defaults 0x9100Command Modes CONFIGURATIONCommand History This guide is platform-specific. For command information about other platforms, see the relevant Dell NetworkingOS Command Line Reference Guide.Version Description9.10(0.0) Introduced on the S6100–ON.9.8(1.0) Introduced on the Z9100–ON.9.8(0.0P5) Introduced on the S4048-ON.9.8(0.0P2) Introduced on the S3048-ON.9.7(0.0) Introduced on the S6000-ON.9.2(1.0) Introduced on the Z9500.9.0.2.0 Introduced on the S6000.8.3.19.0 Introduced on the S4820.8.3.7.0 Introduced on the S4810.8.2.1.0 Introduced on the E-Series. C-Series and S-Series accept both bytes of the 2-byte S-TagTPID.8.2.1.0 Introduced on the E-Series.7.6.1.0 Introduced on the C-Series and S-Series.E-Series originalCommandUsage Information For specific interoperability limitations regarding the S-Tag TPID, see the Dell Networking OS Configuration Guide.The four characters you may enter are shown in the following table.Number Resulting TPID1 0x000110 0x001081 0x00818100 0x8100Related Commands • portmode hybrid — sets a port (physical ports only) to accept both tagged and untagged frames. A portconfigured this way is identified as a hybrid port in report displays.• vlan-stack trunk — specifies a Layer 2 port or port channel as a trunk port to the Stackable VLAN network.vlan-stack trunkSpecify a Layer 2 port or port channel as a trunk port to the stackable VLAN network.Syntax vlan-stack trunk1646 VLAN Stacking