Field FunctionIf channel-to-channel linking is enabled (ELINK = 1), then after the minor loop is exhausted, the eDMAengine initiates a channel service request at the channel defined by this field by setting that channel'sTCDn_CSR[START] bit.NOTE: When the software loads the TCD, this field must be set equal to the corresponding CITER field;otherwise, a configuration error is reported. As the major iteration count is exhausted, thecontents of this field are reloaded into the CITER field.7-15BITERStarting major iteration countAs the transfer control descriptor is first loaded by software, this 9-bit (ELINK = 1) or 15-bit (ELINK = 0)field must be equal to the value in the CITER field. As the major iteration count is exhausted, the contentsof this field are reloaded into the CITER field.NOTE: When the software loads the TCD, this field must be set equal to the corresponding CITER field;otherwise, a configuration error is reported. As the major iteration count is exhausted, thecontents of this field are reloaded into the CITER field. If the channel is configured to execute asingle service request, the initial values of BITER and CITER should be 0x0001.17.4.6.33 TCD Control and Status (TCD0_CSR - TCD31_CSR)17.4.6.33.1 OffsetFor n = 0 to 31:Register OffsetTCDn_CSR 101Eh + (n × 20h)17.4.6.33.2 DiagramBits 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15RBWCMAJORLINKCHDONEACTIVEMAJORELINKESGDREQINTHALFINTMAJORSTARTW0W0CReset u u u u u u u u u u u u u u u u17.4.6.33.3 FieldsField Function0-1BWCBandwidth ControlTable continues on the next page...Chapter 17 Enhanced Direct Memory Access Controller (eDMA)QorIQ LS1012A Reference Manual, Rev. 1, 01/2018NXP Semiconductors 697