E-Series legacycommandRelatedCommandslogging on – enables the logging asynchronously to logging buffer, console, Syslog server, andterminal lines.logging trap – enables logging to the Syslog server based on severity.logging bufferedEnable logging and specify which messages are logged to an internal buffer. By default, all messages are logged to theinternal buffer.C-Series, E-Series, S-Series, Z-SeriesSyntax logging buffered [level] [size]To return to the default values, use the default logging buffered command.To disable logging stored to an internal buffer, use the no logging buffered command.Parameterslevel (OPTIONAL) Indicate a value from 0 to 7 or enter one of the followingequivalent words: emergencies, alerts, critical, errors,warnings, notifications, informational, ordebugging. The default is 7 or debugging.size (OPTIONAL) Indicate the size, in bytes, of the logging buffer. Thenumber of messages buffered depends on the size of each message.The range is 40960 to 524288. The default is 40960 bytes.Defaults level = 7; size = 40960 bytesCommand Modes CONFIGURATIONCommand History Version 8.3.11.1 Introduced on the Z9000.Version 8.3.7.0 Introduced on the S4810.Version 7.6.1.0 Introduced on the S-Series.Version 7.5.1.0 Introduced on the C-Series.E-Series legacycommandUsageInformationWhen you decrease the buffer size, all messages stored in the buffer are lost. Increasing thebuffer size does not affect messages stored in the buffer.RelatedCommandsclear logging – clears the logging buffer.default logging buffered – returns the logging buffered parameters to the default setting.show logging – displays the logging setting and system messages in the internal buffer.1383