Version 8.3.7.0 Introduced on the S4810.Version 8.4.1.0 Added support on the management Ethernet port.Version 8.2.1.0 Introduced on the E-Series ExaScale.Version 7.8.1.0 Introduced on the C-Series and S-Series.Version 7.4.1.0 Introduced on the E-Series TeraScale.UsageInformation • If two addresses are configured, you must delete an existing address beforeconfiguring a new address.• If the last manually-configured global IPv6 address is removed using the “no” form ofthe command, the link-local IPv6 address is removed automatically.• IPv6 addresses on a single management interface cannot be members of the samesubnet.• IPv6 secondary addresses on management interfaces across platform must bemembers of the same subnet.• IPv6 secondary addresses on management interfaces should not match the virtual IPaddress and should not be in the same subnet as the virtual IP.Example FTOS(conf)#interface gigabitethernet 10/0FTOS(conf-if-gi-10/0)#ipv6 address ?X:X:X:X::X IPv6 addressFTOS(conf-if-gi-10/0)#ipv6 address 2002:1:2::3 ?<0-128> Prefix length in bitsFTOS(conf-if-gi-10/0)#ipv6 address 2002:1:2::3 /96 ?FTOS(conf-if-gi-10/0)#ipv6 address 2002:1:2::3 /96FTOS(conf-if-gi-10/0)#show config!interface GigabitEthernet 10/0no ip addressipv6 address 2002:1:2::3 /96no shutdownFTOS(conf-if-gi-10/0)#ipv6 control-plane icmp error-rate-limitConfigure the maximum number of ICMP error packets per second that can be sent per second.S4810Syntax ipv6 control-plane icmp error-rate-limit {1-200}To restore the default value, use the no ipv6 control-plane icmp error-rate-limit command.Parameters pps Enter the maximum number of error packets to be generated persecond. The range is 1 to 200, where 0 disables the rate-limiting.838