7 Product-specific CAN objects XN300 slice modules7.23 XN-322-2DMS-WM306 Gateway XN-312-GW-CAN 06/16 MN050003-EN www.eaton.eu7.23.2 Input Channel x (Object 0x3061 to 0x3062)Objects 0x3061 to 0x3062 represent the analog input valuesDesign of the data bytes:Feature Description / Value EDSName Channel1Input Object 0x3061 [MxSubExt306x]ParameterName=ChannelxInputObjectType=0x7DataType=0x0004AccessType=roPDOMapping=1Count=1Channel2Input Object 0x3062Description Input Channel xObject Code ARRAYMapping PDOManualData type INTEGER32Sub index 01 … FE hexAccess ro1 Byte Byte 0:Sub index1≦n≦254B15B14B13B12B11B10B9B8B7B6B5B4B3B2B1B0LSB4 Byte 3 ByteSub index1≦n≦254B31B30B29B28B27B26B25B24B23B22B21B20B19B18B17B16MSB