Eaton XN-312-GW-CAN manuals
XN-312-GW-CAN
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- About this manual
- Target group
- Device designations and abbreviations
- Writing conventions
- XN-312-GW-CAN gateway
- Overview of functions
- Device overview
- List of I/O slice module products
- Important data for engineering
- Field bus connection
- Baud rate
- Valid device field bus addresses
- Installation
- Setting the Baud rate
- Activate the bus termination resistor for CANopen
- mounting
- Dismantling
- Potential Relationship between the Components
- Connecting the power supply
- Connect field bus
- Connect diagnostics interface
- Wiring in accordance with EMC requirements
- Commissioning
- Switching the gateway on with or without a config check
- In operation
- Switching on when the target configuration is stored
- Take the CANopen field bus into operation
- Creating field bus communication CANopen
- Note on alarms
- Description files for CANopen
- Standard EDS files
- Installing the EDS file
- XSOFT-CODESYS-3
- Connecting the PLC to the gateway using CODESYS
- Configuring the system with XSOFT-CODESYS-2
- Adding the CAN slaves
- Configuring the XN-322 slice modules
- Enabling the default PDOs / manually enabling process data
- Configuring the system with XSOFT-CODESYS-3
- Adding the CAN manager
- Adding CANopen devices
- Configuring XN-322 slice modules
- Automatic PDO mapping
- Manual mapping
- Configuring device initialization parameters
- Adding CANopen communication libraries
- Object dictionary for XN-312-GW-CAN gateway
- Information regarding the XN300 station
- Module Identification Number (Object 0x1027)
- Serial Number XN-312-CANopen (Object 0x4000)
- User LED 1...16 (Object 0x4002)
- User LED 17...32 (Object 0x4003)
- User LED Control (Object 0x4004)
- Product Name Gateway (Object 0x400B)
- Operational readiness monitoring
- Synchronization and emergency identifiers
- Service data transmission
- Process input data transmission
- Product-specific CAN objects XN300 slice modules
- XN-322-8DI-PD
- Read Digital Input 8-Bit (Object 0x6000)
- XN-322-16DI-PD
- XN-322-20DI-PD
- XN-322-20DI-PF
- Read Digital Inputs (Object 0x3030)
- XN-322-20DI-PCNT
- Counter Register (Object 0x3023-0x3026)
- Incremental Encoder Register (Object 0x3027 - 0x3028)
- Counter Mode Register (Object 0x4020)
- XN-322-20DI-ND
- Read Digital Inputs (Object 0x3130)
- XN-322-4DO-RNO
- Write Digital Output 8-bit (Object 0x6200)
- Write Digital Output (Object 0x2120)
- XN-322-8DO-P05
- Write Digital Output (Object 0x2190)
- Input Voltage State (Object 0x3190)
- XN-322-12DO-P17
- Write Digital Output (Object 0x2040)
- InputVoltageState(Object 0x3040)
- XN-322-16DO-P05
- Write Digital Output (Object 0x2050)
- Input Voltage State (Object 0x3050)
- XN-322-8DIO-PD05
- Write Digital Output (Object 0x2180)
- Input Voltage State (Object 0x3181)
- XN-322-16DIO-PD05
- Read Digital Inputs (Object 0x3160)
- Input Voltage State (Object 0x3161)
- XN-322-16DIO-PC05
- Write Digital Output (Object 0x2170)
- Input Voltage State (Object 0x3171)
- Incremental Encoder Register (Object 0x3176 bis 0x3177)
- PWM High Time (Object 0x3178, 0x317A, 0x317C, 0x317E)
- PWM Period Time (Object 0x3179, 0x317B, 0x317D, 0x317F)
- Counter Mode Register (Object 0x4170)
- XN-322-4AI-PTNI
- Read Analog Input 16-Bit (Object 0x6401)
- Analog Input Interrupt Trigger Selection (Object 0x6421)
- Analog Input Interrupt Upper Limit Integer (Object 0x6424)
- Analog Input Interrupt Lower Limit Integer (Object 0x6425)
- Analog Input Interrupt Delta Unsigned (Object 0x6426)
- Analog Input Interrupt Negative Delta Unsigned (Object 0x6427)
- Analog Input Interrupt Positive Delta Unsigned (Object 0x6428)
- Module Diagnostic Messages (Object 0x3070)
- Input Channel x (Object 0x3071 to 0x3074)
- Wire Break Diagnostic Messages (Object 0x3075)
- Range Diagnostic Messages (Object 0x3076)
- Native Data Analog Input x (Object 0x3077 to 0x307E)
- Sensor Type Selection Channel x (Object 0x5070 bis 0x5073)
- Channel Measuring Configuration (Object 0x5074)
- Filter Configuration Channel x (Object 0x5075 to 0x5078)
- Channel Activation (Object 0x5079)
- XN-322-7AI-U2PT
- Analog Input Global Interrupt Enable (Object 0x6423)
- Module Diagnostic Messages (Object 0x3080)
- Input Channel x (Object 0x3081 to 0x3087)
- Wire Break Diagnostic Messages (Object 0x3088)
- Firmware Version (Object 0x4080)
- Channel Measuring Configuration (Object 0x5080)
- Filter Configuration Channel x (Object 0x5081 to 0x5086)
- XN-322-8AI-I
- Module Diagnostic Messages (Object 0x3090)
- Input Channel x (Object 0x3091 to 0x3098)
- Wire Break Diagnostic Messages (Object 0x3099)
- Firmware Version (Object 0x4090)
- Channel Measuring Configuration (Object 0x5090)
- Channel x Filter Configuration (Object 0x5091 to 0x5098)
- XN-322-10AI-TEKT
- Module Diagnostic Messages (Object 0x30A0
- Input Channel x (Object 0x30A1 to 0x30A8)
- Reference Input Channel x (Object 0x30A9 to 0x30AA)
- Firmware Version (Object 0x40A0)
- Reference Input Select (Object 0x50A4)
- XN-322-8AO-U2
- Write Analog Output 16-Bit (Object 0x6411)
- Output Channel x (Object 0x20D0 to 0x20D7)
- Module Diagnostic Messages (Object 0x30D0)
- Firmware Version (Object 0x40D0)
- XN-322-4AIO-U2
- Output Channel x (Object 0x21A0 bis 0x21A1)
- Module Diagnostic Messages (Object 0x31A0)
- Input Channel x (Object 0x31A1 to 0x31A2)
- Firmware Version (Object 0x41A0)
- Analog Input Selection (Object 0x51A0)
- Filter Configuration Channel x (Object 0x51A1 bis 0x51A2)
- XN-322-8AIO-U2
- Output Channel x (Object 0x20B0 to 0x20B3)
- Input Channel x (Object 0x30B1 to 0x30B4)
- Firmware Version (Object 0x40B0)
- Analog Input Selection (Object 0x50B0)
- Filter Configuration Channel x (Object 0x50B1 to 0x50B4)
- XN-322-4AIO-I
- Output Channel x (Object 0x21B0 to 0x21B1)
- Module Diagnostic Messages (Object 0x31B0)
- Input Channel x (Object 0x31B1 to 0x31B2)
- Input Voltage State (Object 0x31B4)
- Firmware Version (Object 0x41B0)
- Input Channel Configuration (Object 0x51B0)
- Output Channel Configuration (Object 0x51B1)
- Filter Configuration Channel x (Object 0x51B2 to 0x51B3)
- XN-322-8AIO-I
- Output Channel x (Object 0x20C0 bis 0x20C3)
- Module Diagnostic Messages (Object 0x30C0)
- Input Channel x (Object 0x30C1 bis 0x30C4)
- Input Voltage State (Object 0x30C6)
- Firmware Version (Object 0x40C0)
- Output Channel Configuration (Object 0x50C1)
- Filter Configuration Channel x (Object 0x50C2 bis 0x50C5)
- XN-322-2DMS-WM
- Module Diagnostic Messages (Object 0x3060)
- Input Channel x (Object 0x3061 to 0x3062)
- Analog Digital Converter Diagnostic Messages (Object 0x3063)
- Firmware Version (Object 0x4060)
- Range Configuration Channel x (Object 0x5061, 0x5063)
- Zero-Scale Channel x (Object 0x5064, 0x5066)
- Full-Scale Channel x (Object 0x5065, 0x5067)
- XN-322-1DCD-B35
- Write PWM Sequenz Data (Object 0x20E0 to 0x20E3)
- Write Period Duration of Sequence Cycle (Object 0x20E4)
- ON Time PWM LED x (Object 0x20E5, 0x20E6)
- Motor Control (Object 0x20E7)
- Read PWM Sequenz Data (Object 0x30E0 to 0x30E3)
- Read Period Duration of Sequence Cycle (Object 0x30E4)
- DC Driver Temperature (Object 0x30E5)
- DC Motor Diagnosis (Object 0x30E7)
- DC Motor Status (Object 0x30E8)
- Module Diagnostic Messages (Object 0x30EA)
- Firmware Version (Object 0x40E0)
- PWM Period Duration Register LED x (Object 0x40E3, 0x40E4)
- DC Motor I2T Value Limit (Object 0x40E5)
- XN-322-1CNT-8DIO
- Write Digital Outputs (Object 0x20F0)
- Read Digital Input (Object 0x30F0)
- Encoder Idle Time (Object 0x30F1)
- Encoder Measuring Value (Object 0x30F2)
- Encoder Status (Object 0x30F4)
- Latch Input Configuration (Object 0x40F0)
- Encoder Type Configuration (Object 0x40F1)
- Maximum Idle Time (Object 0x40F2)
- Idle Clock Pre-Scaler (Object 0x40F3)
- System Clock Frequency (Object 0x40F4)
- Encoder Signal Configuration (Object 0x40F6)
- Encoder Status SDO (Object 0x40F7)
- Encoder Latch Value SDO (Object 0x40F8)
- XN-322-2SSI
- Start Read Cycle (Object 0x2100)
- Read Cycle State (Object 0x3100)
- Module Diagnosis (Object 0x3101)
- Input Channel x (Object 0x3102 to 0x3103)
- Channel Configuration Register (Object 0x4100, 0x4102)
- Channel Transmission Configuration Register (Object 0x4101 0x4103)
- Station variants
- How the "station variants" operating mode works
- General principles / behavior of the gateway and the PLC
- Startup behavior
- Station Variants" function block
- Overview
- Handling on the PLC
- XN300-Assist
- CAN objects for station variants
- Module list (internal) (Object 0x4007)
- Available Modules (internal) (Object 0x4008)
- What Happens If
- Appendix
- Dimensions
- Technical Data
- XN-322 slice modules
- Maximum number of process data objects
- Index
Related products
XN-312-GW-ECXN-GW SeriesXN-GWBR-PBDPXN-GWBR SeriesXNE-GWBR-2ETH-MBSWIRE-GW-MBINDGW-X2Moeller SmartWire-Darwin EU5C-SWD-CANPower Xpert Gateway 900Power Xpert Gateway 200EEaton categories
Circuit breakers
Industrial Equipment
Industrial Electrical
UPS
Switch
Control Unit
Controller
Accessories
Relays
Water Pump
manualsdatabase
Your AI-powered manual search engine