show hg-link-bundle-distributionDisplay the operational status and link utilization in a HiGig link bundle.C9000 SeriesSyntax show hg-link-bundle-distribution {sfm npu-id hg-port—channel hg-port—channel-id | slot slot npuUnit npu-id hg-port—channel 0}enableParameters sfm npu-id hg-port-channel hg-port-channel-idSpecify a HiGig port channel on a switch SFM (spine) NPU byentering the keyword sfm and SFM NPU ID, then hg-port-channel and a HiGig port channel ID. SFM NPU ID is 0; SFMHiGig port-channel IDs are 0 to 10.slot slot-idnpuUnit npu-idhg-port-channel0Specify a HiGig port channel on a line-card (leaf) NPU byentering the keyword slot and slot number, then npuUnit andNPU ID, then hg-port-channel 0. Line-card slot numbers are0 to 11; line-card NPU ID is 0. The HiGig port-channel ID is from0 to 2.Command Modes EXEC, EXEC PrivilegeCommand History Version Description9.9(0.0) Introduced on the C9010.9.2.(1.0) Introduced on the Z9500.9.3.0.0 Introduced on the Z9000.Usage Information The following table illustrates the fields displayed in the output of this command:Table 3. show hg-link-bundle-distribution Command DescriptionField DescriptionLink-bundle trigger threshold Percentage value of link-bundlebandwidth that serves as the thresholdfor marking a link bundle as beingoverutilized, triggering link-bundlemonitoring, and generating an SNMPalarm.Slot Slot number of a line card.npuUnit Network processing unit (NPU) IDnumber of a HiGig link bundle/port-channel.Interfaces 1038