Connecting the motor cablesNoteActionxx1300000738Push the motor cables in through the cablegland opening.1xx1200001016Refit the cable gland cover by performingthe following steps:• Slide the cable gland cover onto theinner screw.• Refit and tighten the outer screw.• Tighten the inner screw. Make surethat the gasket is not damaged.NoteReplace the gasket if damaged!2xx1200001015Connect the connectors.Connect in accordance with the markingson the connectors.3Continues on next page436 3HAC044266-001 Revision: -© Copyright 2013 ABB. All rights reserved.4 Repair4.7.5 Replacing the axis-5 motorContinued