Version 8.3.11.1 Introduced on the Z9000.Version 8.3.7.0 Introduced on the S4810.Version 7.6.1.0 Introduced on the S-Series.Version 7.5.1.0 Introduced on the C-Series.Version 6.1.1.0 Introduced on the E-Series.rmon hc-alarmSet an alarm on any MIB object.S4810Syntax rmon hc-alarm number variable interval {delta | absolute}rising-threshold value event-number falling-threshold valueevent-number [owner string]To disable the alarm, use the no rmon hc-alarm number command.Parameters number Enter the alarm integer number from 1 to 65535. The valuemust be unique in the RMON alarm table.variable The MIB object to monitor. The variable must be in theSNMP OID format; for example, 1.3.6.1.2.1.1.3 The objecttype must be a 64-bit integer.interval Time, in seconds, the alarm monitors the MIB variables; thisis the alarmSampleType in the RMON alarm table. The rangeis from 5 to 3600 seconds.delta Enter the keyword delta to test the change between MIBvariables. This is the alarmSampleType in the RMON alarmtable.absolute Enter the keyword absolute to test each MIB variabledirectly. This is the alarmSampleType in the RMON alarmtable.rising-threshold valueevent-numberEnter the keywords rising-threshold then the value (64bit) the rising-threshold alarm is either triggered or reset.Then enter the event-number to trigger when the risingthreshold exceeds its limit. This value is the same as thealarmRisingEventIndex or alarmTable of the RMON MIB. Ifthere is no corresponding rising-threshold event, the value iszero.Remote Monitoring (RMON) 1413