Switch Management Commands 2009• owner—Enter a name that specifies who configured this event. Ifunspecified, the name is an empty string.Default ConfigurationThis command has no default configuration.Command ModeGlobal Configuration modeUser GuidelinesThis command has no user guidelines.ExampleThe following example configures an event with the trap index of 10.console(config)#rmon event 10 logrmon hcalarmUse the rmon hcalarm to configure high capacity alarms.Use the no form ofthe command to remove the alarm.Syntaxrmon hcalarm alarmnumber variable interval {absolute | delta} rising-threshold value-64[rising-event-index] falling-threshold value-64[falling-event-index] [startup {rising | falling | rising-falling}] [owner string]• alarmnumber—An alarm number that uniquely identifies the alarmentry. (Range: 1-65536). Each entry defines a diagnostic sampler at aparticular interval for an object on the device.• variable—The MIB object to monitor. May be fully qualified or relative.Only variables that resolve to an ASN.1 primitive type of INTEGER areallowed.• interval—The interval in seconds over which the data is sampled andcompared with the rising and falling thresholds. (Range: 1– 2147483647.The default is 1 second.)