Switch Management Commands 2170To disconnect a remote session to the stack master established from a stackmember.(Unit 2 - CLI unavailable - please connect to master on Unit 1)>connect 2(Unit 2 - CLI unavailable - please connect to master on Unit 1)>(Unit 2 - CLI unavailable - please connect to master on Unit 1)>connect 1Stack-Master#Stack-Master#exitStack-Master>exit(Unit 2 - CLI unavailable - please connect to master on Unit 1)>hardware profile portmodeUse the hardware profile portmode command in Interface Configurationmode to configure a 40G port in 4x10G mode or 1x40G mode.Use the no form of the command to return the port to the default mode(1x40G).Syntaxhardware profile portmode {1x40g|4x10g}no hardware profile portmode• 1x40g—Configure the port as a single 40G port using 4 lanes.• 4x10g—Configure the port as four 10G ports, each on a separate lane.This mode requires the use of a suitable 4x10G to 1x40g pigtail cable.Default ConfigurationBy default, 40G ports are configured in 1x40G mode.Command ModeInterface Configuration modeUser GuidelinesThis command is only available on the N4000 series switches. This commandcan only be executed on the 40G interface. Entering this command on any ofthe 4x10G interfaces (or any other 10G port) will give an error.