Layer 2 Switching Commands 409ExampleThe following example shows the qualifications status of the optics on theswitch.console#show interfaces transceiverPort Dell Qualified------------- ----------------Te1/0/9 YesTe1/0/11 YesTe1/0/13 N/ATe1/0/15 NoTe1/0/17 NoThe following example shows static parameters of the optics along with thequalifications status.console#show interfaces transceiver propertiesYes: Dell Qualified No: Not QualifiedN/A : Not ApplicablePort Type Media Serial Number Dell Qualified------------ ------- --------------- -------------------- --------------Te1/0/9 SFP+ 10GBASE-LRM ANF0L5J YesTe1/0/11 SFP+ 10GBASE-LRM ANF0L5R YesTe1/0/13 SFP 1GBASE-SX PCC1PT5 N/ATe1/0/15 SFP+ 10GBASE-SR AD1125A002R NoTe1/0/17 SFP+ 10GBASE-SR AD0815E00PC Noshow statisticsUse the show statistics command to display detailed statistics for a specificport or for the internal CPU interface.Syntaxshow statistics {gigabitethernet unit/slot/port |switchport | port-channelport-channel-number | tengigabitethernet unit/slot/port |fortygigabitethernet unit/slot/port}• unit/slot/port—A valid physical interface identifier. See Interface NamingConventions for interface representation.• port-channel-number—A port channel identifier.• switchport—Displays statistics for the internal switch CPU interface.