Layer 2 Switching Commands 435show ethernet cfm maintenance-points localUse the show ethernet cfm maintenance-points local command to displaythe configured local maintenance points.Syntaxshow ethernet cfm maintenance-points local {level 0-7 | interface interface-id | domain domain-name}• level—Maintenance association level• domain—Name of the maintenance domain (an alphanumeric string ofup to 43 characters in length).• interface-id—Show all MPs associated with the interface. This commandaccepts physical interface identifiers and port channel interface identifiers.Default ConfigurationThis command has no default configuration.Command ModePrivileged Exec, Global Configuration mode and all Configuration submodesUser GuidelinesRefer to IEEE 802.1ag for an explanation of the maintenance associationlevel and MEP ID. Typically, these are assigned by the top level networkservice provider.• MPID—The maintenance endpointoint identifier• Level—The MEP level• Type—Maintenance endpoint (MEP) or maintenance intermediate point(MIP)• VLAN—The configured VLAN id• Port—The port on which the MEP association is configured• Direction—(Up)stream or (Do)wnstream• CC Transmit—Continuity check enabled• MEP-Active—The MEP administrative status