Security Commands 890E-mail Alerting CommandsDell EMC Networking N1100-ON/N1500/N2000/N2100-ON/N3000/N3100-ON/N4000 Series SwitchesE-mail Alerting is an extension of the logging system. The Dell EMCNetworking logging system allows the user to configure a variety ofdestinations for log messages. This feature adds e-mail configurationcapabilities, by which the log messages are sent to a configured SMTP serversuch that an operator may receive the log in an e-mail account of their choice.Figure 1: Log Messages Severity LevelThe network operator can adjust the urgent and non-urgent severity levels.These levels are global and apply to all destination e-mail addresses. Logmessages in the urgent group are sent immediately to SMTP server with eachlog message in a separate mail. Log messages in the non-urgent group arebatched into a single e-mail message and after a configurable delay.Only the minimum part (MUA functionality of RFC 4409) required by theswitch or router to send the messages to the SMTP server is supported. SomeSMTP servers insist on authentication before the messages may be receivedby them. The minimum part (MUA functionality of RFC 4954) required bythe switch or router to become authenticated by the SMTP server issupported. Only plain text authentication is supported.Commands in this SectionThis section explains the following commands: