Switch Management Commands 2172initiate failoverTo manually force a failover from the management unit to the backup unit ina stack, use the initiate failover command in Stack Configuration mode.The initiate failover command checks for stack port errors and NSFsynchronization prior to initiating failover. If stack port errors are found, or ifthe NSF status is not synchronized, a message is displayed and the user isprompted to continue or abort the operation (see example, below).Syntaxinitiate failoverDefault ConfigurationThere is no default configuration.Command ModeStack Configuration modeUser GuidelinesThis command forces a warm restart of the stack. The backup unit takes overas the new management unit without clearing the hardware state on any ofthe stack members. The original management unit reboots. If the system isnot ready for a warm restart, for example because no backup unit has beenelected or one or more members of the stack do not support nonstopforwarding, the command fails with a warning message. Use the standbycommand to select a specific unit to act as the backup unit. Use the show nsfcommand to check the NSF state. If the switch shows Warm Restart Ready asYes, then the master switch state is synchronized with the standby switch.ExamplesExample-No Stack Port Errorsconsole(config-stack)#initiate failover ? Press enter to execute the command.console(config-stack)#initiate failoverManagement unit will be reloaded.Are you sure you want to failover to the backup unit? (y/n) y