USER’S GUIDE256 CyberSWITCH9. If IPX RIP has been enabled for the system, enter the following:a. RIP send control (do not respond or respond)b. frequency (in seconds) of sending RIP updatesc. RIP receive control (do not respond or respond)d. time (in seconds) to age RIP entriese. RIP respond control (do not respond or respond)10. If IPX SAP has been enabled for the system, enter the following:a. SAP send control (do not respond or respond)b. frequency (in seconds) of sending SAP updatesc. SAP receive control (do not respond or respond)d. time (in seconds) to age SAP entriese. SAP respond control (do not respond or respond)11. After all the interface information has been entered, a summary screen will be displayedsimilar to the sample screen below:12. As shown above, enter “Y” to save the interface configuration.13. Repeat this procedure to add additional interfaces.U SING M ANAGE M ODE C OMMANDSipxnetifDisplays the current IPX network interface data.ipxnetif [add/change/delete]Allows you to add/change/delete an IPX network interface.Current Configuration for INTERFACE "lanport1":Interface Type LANIPX Network Number 11111111MTU (bytes) 1497Encapsulation Ethernet 802.2LAN Port 1RIP Configuration:Send Control SendSend Frequency 60 secondsReceive Control ReceiveRIP entry Ageing Time 180 secondsRespond Control RespondSAP Configuration:Send Control SendSend Frequency 60 secondsReceive Control ReceiveSAP entry Ageing Time 180 secondsRespond Control RespondAre you sure you want to add the INTERFACE "lanport1" (Y or N) [Y]? Y