USER’S GUIDE442 CyberSWITCHNetwork sent Cause - SPID not supported - The indicated line does not support SPIDs; however, a SPID is configured for use on the line. Is theSPID configured incorrectly? Do you have the right switch type? Check the configuration. If themessage persists, contact your BRI provider to determine corrective action.Network sent STATUS with state = 0, tear down callA STATUS message has been received from the network indicating that a specified call is not active.The system is removing the call.No Active Calls0 Active SitesCurrently, no sites are connected to the system.No Active List entry available in INMThe system tried to contact a remote site and no table entries were available. You may need a largerversion of the CyberSWITCH.No CCB found, Port=, CallRef=Contact your Distributor or Customer Support. Provide your distributor with a copy of themessage log, and the output of thewan stats command. With thewan stats command, themain item of interest is the “rcv fail” number on the connections line.No compression sessions are available due to memory constraints.Check available memory; upgrade to a 12Mb system (minimum). If you are still encounteringproblems, disable unused protocols, and/or contact your Distributor or Customer Support toreduce your number of available connections.NO FR LMI transmit buffer availableIndicates that, temporarily, no transmit buffer was available for formatting and sending a STATUSENQUIRY message to the network.NO FR LMI transmit buffer descriptor availableIndicates that, temporarily, no transmit buffer descriptor was available for control andadministration of a STATUS ENQUIRY message to be sent to the network.No internal b channel resources available, disconnecting callThe call is up, but there are no resources available to send the data. Contact your Distributor orCustomer Support.No resources available to accept incoming callThe System received an incoming call, but it had already established the maximum number of calls.This indicates the demand for network resources exceeds the configuration of this system. If thistype of occurrence continues, you should consider upgrading to a larger system.No response to TEI requests - Slot= Port= Ces=TEI configuration mismatch between the system and the switch for the indicated line. Theconfiguration of the system or of the switch should be corrected.No Sites ConnectedCurrently, no sites are connected to the system. PreviousNext |