Small Office Remote Access Switch 449SYSTEM M ESSAGESSystem Message SummarySecurity Rejection - No Password given by callerA properly formed Bridge Security negotiation packet was received, and the bridge is registered inthe system Device Table, but a password is required and none was provided by the calling bridge.Check configuration. If problem persists, contact your Distributor or Customer Support.Security Rejection - No Protocol List suppliedA Combinet has attempted to connect to the system without the required Protocol List information.Check configuration, and then reboot the Combinet. If problem persists, contact your Distributoror Customer Support.Security Rejection - Timeout on Startup CompleteAfter a normal Bridge Security negotiation packet is received, and the System sends a responsemessage, there is a five second time limit in which a “Startup Complete” message must be received.The above security rejection message is seen if the Startup Complete message is not received beforethe timer expires. Check to see if the response message was received by the calling bridge.Security Rejection - Unknown Calling Bridge - A properly formed Bridge Security negotiation packet was received but the bridge address is notregistered in the system Device Table.SemiPermanent. Local authentication failure of Semipermanent device "x"The system failed to authenticate the indicated device. The semipermanent connection will bedisabled. Compare the authentication device information configured on the system with the actualconfiguration of the remote device. Make corrections as needed. Then, issue thecall device name> command to reinstate the semipermanent connection.Semipermanent. Device "x" disconnected by adminThe administrator has issued adisc device command. Therefore, the systemwill not attempt to call the indicated device again. Issuing thecall device name>command will make device “x” semipermanent again.Semipermanent. Device "x" has a smaller Initial Data Rate than Base Data Rate. No connection made.The semipermanent feature will make enough calls to meet but not exceed the device’s Initial DataRate. In this case, the Base Data Rate (normally 56 or 64 Kbps) is larger than the device’s Initial DataRate. The semipermanent feature cannot make any calls, or it will exceed the Initial Data Rate.Reconfigure your data rates.Semipermanent. Device "x" has had "y" bandwidth drops within "z" seconds. This device is considered tohave failed remote authentication.Because the local system cannot always be aware of remote authentication failures, and becausethere is no way to recognize remote authentication failures in the system once the remote end isauthenticated, the semipermanent feature will try to determine them by detecting excessive remotebandwidth drops. The remote device must drop a call 10 times within a 10 minute period to triggerthis event.Will try again in "w" minutes.This will be displayed directly beneath the above message if a Session Interval isconfigured for the device.