Small Office Remote Access Switch 401LED I NDICATORSService IndicatorSERVICE I NDICATOR REMAINS L ITIf the Service indicator remains lit during the power-on sequence, this means the system softwareis unable to boot. The system may be having some type of operational problem. While the Serviceindicator remains lit, the other LEDs will blink a certain number of times, pause, then blink thatnumber of times again (See following table). This pattern will be repeated five times. The actions totake if this occurs are:1. Make note of the number of consecutive blinks.2. Restart the system.3. If the Service LED is still lit, and the other LEDs are still flashing, contact your distributor andprovide them with the count of consecutive blinks.The table below provides an error description corresponding to the number of consecutive LEDblinks:* FSB: First Stage Boot; SSB: Second Stage Boot.SERVICE I NDICATOR BLINKSIf the Service indicator blinks at any time during system operation, access your administrativeconsole (using the status command) for further information. One or more of the following messagesshould be displayed:• OUT SVC 1• OUT SVC 2• OUT SVC 3• OUT SVC 4• OUT SVC 5• LAN XMIT ERRORNumber of Blinks Error Description1 Failure during erasure of main block during SSB* recovery2 Failure during programming of main block during SSBrecovery3 Timed out during recovery of SSB4 Individual record error during recovery of SSB5 Communications error during recovery of SSB6 Incompatibility between FSB* and new SSB versions7 Currently not used8 Bad address information contained in SSB received duringrecovery9 SSB, received during Recovery, contained a bad checksumfor entire image